| LCD Display |
SI3100 LVDT,
SI3200 Half Bridge |
SI3300 4 - 20 mA/Voltage |
| Digital |
1 Colour |
2x or 1 Colour |
| Analogue |
1 Vertical Bar |
2x Colour Horizontal Bar or 1 Vertical Bar |
| Update Speed |
40 Hz |
| Display Length (metric) - User Selectable |
± XX.XXXXX mm |
| Display Length (imperial) - User Selectable |
± X.XXXXXX " |
| Resolution (metric) - User Selectable |
Down to 0.05 µm |
| Resolution (imperial) - User Selectable |
Down to 0.000005 " |
|
| Inputs |
| Signal Input |
LVDT (SI3100) or 2 Half Bridge (SI3200) |
Wire Loop powered 4 - 20 mA (loop excitation 15 V nominal), 0 - 5 V, 0 - 10 V, ± 5 V, ± 10 V |
| Number of Inputs |
2 |
|
| Keypad |
| Membrane (9 keys) |
Print, Zero, Up, Down, Left, Right, Enter, Peak/Hold/Track, Menu |
| Measurement Types |
A, B, A+B, A-B, (A+B)/2, (A-B)/2, (B/A)/a |
A, B, A+B, A-B, (A+B)/2, (A-B)/2, (B/A)/a, X and Y |
| Data Logging |
- |
10 000 readings via switch or 1 ms to 24 hour time interval |
| Indications |
mm/inch, Lower & Upper Limits, Out of Range, Measurement Mode |
| Power Requirements |
+24 VDC ± 10% |
|
| External I/O |
| Serial |
RS232 Serial Port (for Printer or PC) |
| Discrete Output |
2 x 3 isolated |
| Analogue Output |
2 Channels DC or 4 - 20 mA |
|
| Environmental |
| Operating Temperature (°C) |
0 to +50 |
| Storage Temperature (°C) |
-20 to +50 |
| Electrical Immunity |
EN61000-6-2:2001 |
| Electrical Emissions |
EN61000-6-3:2001 |
| Front Panel Sealing |
IP 65 |
|
| Mechanical |
| Mounting |
Bench Top or Panel Mount |
| Dimensions WxHxD (mm) |
Without Bezel: 134 x 65 x 160
With Bezel: 144 x 74 x 175 |